Note:
Parameter
A1-02 [Control Method Selection]
selects which parameter is the reference.
A1-02 Setting
Control method selection
Parameter Used as the Reference
0
V/f Control
E1-09
1
V/f Control with Encoder
E1-09
2
Open Loop Vector
b2-01
3
Closed Loop Vector
E1-09
4
Advanced OpenLoop Vector Control
E1-09
5
PM Open Loop Vector
E1-09
6
PM Advanced Open Loop Vector
E1-09
7
PM Closed Loop Vector Control
b2-01
8
EZ Open Loop Vector Control
E1-09
Figure 2.90 Zero Speed Time Chart
ON : Output frequency < value of
E1-09
or
b2-01
.
OFF : Output frequency
≥
value of
E1-09
or
b2-01
.
■
2: Speed Agree 1
Setting Value
Function
Description
2
Speed Agree 1
The terminal turns on when the output frequency is in the range of the frequency reference ±
L4-02 [Speed Agree Detection Width]
.
Note:
•
The detection function operates in the two motor rotation directions.
•
The drive outputs the motor speed status when
A1-02 = 3, 7 [CLV, CLV/PM]
. It also outputs the motor speed status when
A1-02 = 4
and
n4-
72 = 1
.
Figure 2.91 Speed Agree 1 Time Chart
ON : The output frequency is in the range of “frequency reference
±
L4-02
”.
OFF : The output frequency does not align with the frequency reference although the drive is
running.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV