Precautions before Operation
Before rotating the motor, check these items:
•
Check for safety issues near the drive, motor, and machine.
•
Make sure that all emergency stop circuits and machine safety mechanisms are operating correctly.
•
Make sure that the motor is fully stopped.
•
Connect the motor with the machine.
Make sure that there are no loose installation screws and that the motor load shafts and machine junctions are
correctly secured.
•
Keep the keypad near you to push
immediately if there is unusual or incorrect operation.
■
Items to Check before Operation
•
Make sure that the direction of the machine operation is correct (The motor must rotate in the correct direction).
•
Make sure that the motor accelerates and decelerates smoothly.
◆
Do an Actual-Load Test Run
Connect the motor and machine, then do the test run with the same procedure you used for the no-load test run.
•
Make sure that
U1-03 [Output Current]
is not too high.
1.
Energize the drive, or push
(Home) to show the HOME screen.
If [Home] is not shown on
, push
(Back) to show [Home] on
2.
Set
d1-01 [Reference 1]
to 6.00 Hz.
3.
Push
to illuminate the LOCAL/REMOTE indicator.
4.
Push
.
The RUN indicator illuminates, and the motor runs at 6.00 Hz in the forward direction.
5.
Make sure that the motor is rotating in the correct direction and that the drive does not show a fault.
If the drive detects a fault, remove the cause.
6.
Push
to increase the frequency reference value.
Change the setting value in increments of 10 Hz if necessary and examine the response.
7.
Each time you increase the setting value, use
U1-03 [Output Current]
to check the drive output current.
When the output current of the drive is not more than the motor rated current, the status is correct.
Ex.: 6 Hz → 20 Hz → 30 Hz → 40 Hz → 50 Hz → 60 Hz
8.
Make sure that the motor rotates correctly, then push
.
The RUN indicator will flash. When the motor stops, the indicator will go out.
9.
Change the frequency reference and direction of motor rotation, and make sure that there are no unusual
sounds or vibrations.
10.
If there are hunting or oscillation errors caused by control function, adjust the settings to stop the errors.