YASKAWA
TOEPYAIGA8002B GA800 Drive Programming
79
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
H6-03
(042E)
RUN
Terminal RP Function
Gain
Sets the gain used when the function in
H6-01 [Terminal RP Pulse Train Function]
is input
to terminal RP.
100.0%
(0.0 - 1000.0%)
H6-04
(042F)
RUN
Terminal RP Function
Bias
Sets the bias used when the function in
H6-01 [Terminal RP Pulse Train Function]
is input
to terminal RP. Sets a value at the time when the pulse train is 0 Hz.
0.0%
(-100.0 - 100.0%)
H6-05
(0430)
RUN
Terminal RP Filter Time
Sets the time constant for the pulse train input primary delay filters.
0.10 s
(0.00 - 2.00 s)
H6-06
(0431)
RUN
Terminal MP Monitor
Selection
Sets a function for pulse train monitor output terminal MP. Sets the
“
x-xx
”
part of the
Ux-xx
monitor.
102
(000, 031, 101, 102, 105,
116, 501, 502, 801 - 809,
821 - 825, 831 - 839, 851
- 855)
H6-07
(0432)
RUN
Terminal MP Frequency
Scaling
Sets the frequency of the pulse train output signal used when the monitor set with
H6-06
[Terminal MP Monitor Selection]
is 100%.
1440 Hz
(0 - 32000 Hz)
H6-08
(043F)
Terminal RP Minimum
Frequency
Sets the minimum frequency of the pulse train signal that terminal RP can detect.
0.5 Hz
(0.1 - 1000.0 Hz)
H6-09
(156E)
Voltage Phase Sync MP
Selection
Set whether to output the pulse synchronized with drive output voltage phase from the
pulse train monitor output terminal MP. This parameter is only enabled when
H6-06 = 102
[Terminal MP Monitor Selection = Output Frequency]
and
H6-07 = 0 [Terminal MP
Frequency Scaling = 0 Hz]
.
0 : Disabled
1 : Enabled
0
(0, 1)
◆
H7: Virtual MFIO selection
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
H7-00
(116F)
Expert
Virtual MFIO selection
Sets the function to enable and disable the virtual I/O function. Set this parameter to 1 to
operate the virtual I/O function.
0 : No
1 : Yes
0
(0, 1)
H7-01
(1185)
Expert
Virtual Multi-Function
Input 1
Sets the function that enters the virtual input set in
H7-10 [Virtual Multi-Function Output
1]
.
Note:
Settings
1B [Programming Lockout]
and
11B [!Programming Lockout]
are not
available.
F
(1 - 19F)
H7-02
(1186)
Expert
Virtual Multi-Function
Input 2
Sets the function that enters the virtual input set in
H7-12 [Virtual Multi-Function Output
2]
.
Note:
Settings
1B [Programming Lockout]
and
11B [!Programming Lockout]
are not
available.
F
(1 - 19F)
H7-03
(1187)
Expert
Virtual Multi-Function
Input 3
Sets the function that enters the virtual input set in
H7-14 [Virtual Multi-Function Output
3]
.
Note:
Settings
1B [Programming Lockout]
and
11B [!Programming Lockout]
are not
available.
F
(1 - 19F)
H7-04
(1188)
Expert
Virtual Multi-Function
Input 4
Sets the function that enters the virtual input set in
H7-16 [Virtual Multi-Function Output
4]
.
Note:
Settings
1B [Programming Lockout]
and
11B [!Programming Lockout]
are not
available.
F
(1 - 19F)
H7-10
(11A4)
Expert
Virtual Multi-Function
Output 1
Sets the function for virtual digital output 1.
F
(0 - 1A7)
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV