YASKAWA
TOEPYAIGA8002B GA800 Drive Programming
375
Figure 2.85 DC Injection Braking Time Chart
Note:
•
When
A1-02 = 8 [Control Method Selection = EZOLV]
, this function is available only when you use a PM motor.
•
Refer to "b2: DC Injection Braking and Short Circuit Braking" for more information.
■
61: Speed Search from Fmax
Setting Value
Function
Description
61
Speed Search from Fmax
Sets the function to start speed search using an external reference although
b3-01 = 0 [Speed Search Selection at Start = Disabled]
.
When the terminal is turned ON for
b3-24 = 2 [Speed Search Method Selection = Current Detection 2]
, the drive
starts speed search from the maximum output frequency.
Note:
•
The drive will detect
oPE03 [Multi-Function Input Setting Err]
when
H1-xx = 61 and 62
are set at the same time.
•
Refer to
“
b3: Speed Search
”
for more information.
■
62: Speed Search from Fref
Setting Value
Function
Description
62
Speed Search from Fref
Sets the function to use an external reference to start speed search although
b3-01 = 0 [Speed Search Selection at Start = Disabled]
.
When the terminal is turned ON for
b3-24 = 2 [Speed Search Method Selection = Current Detection 2]
, the drive
starts speed search from the frequency reference.
Note:
•
The drive will detect
oPE03 [Multi-Function Input Setting Err]
when
H1-xx = 61 and 62
are set at the same time.
•
Refer to
“
b3: Speed Search
”
for more information.
■
63: Field Weakening
Setting Value
Function
Description
63
Field Weakening
Sets the function to send the Field Weakening Level and Field Weakening Frequency Limit commands set in
d6-01[Field
Weakening Level] and d6-02 [Field Weakening Frequency Limit]
when the input terminal is activated.
Note:
Refer to
“
d6: Field Weak & Field Force
”
for more information.
■
65: KEB Ride-Thru 1 Activate (N.C.)
Setting Value
Function
Description
65
KEB Ride-Thru 1 Activate
(N.C.)
Sets operation of the KEB1 function through the KEB Ride-Thru 1 (N.C.).
ON : Normal operation
OFF : Deceleration during momentary power loss
When you enable KEB Ride-Thru 1, set
L2-29 [KEB Method Selection]
. The drive operates with the selected KEB
method.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV