1.21 Defaults by Drive Model and Duty Rating ND/HD
142
YASKAWA
TOEPYAIGA8002B GA800 Drive Programming
No.
Name
Unit
Default
-
Drive Model
-
4009
4012
4018
4023
C6-01
Normal /
Heavy Duty
Selection
-
HD
ND
HD
ND
HD
ND
HD
ND
0
1
0
1
0
1
0
1
o2-04
Drive Model
(KVA)
Selection
Hex.
96
97
99
9A
E2-11
(E4-11, E5-
02)
Motor Rated
Power
HP (kW)
4
(3.0)
5
(4.0)
5
(4.0)
7.5
(5.5)
7.5
(5.5)
10
(7.5)
10
(7.5)
15
(11)
b3-04
V/f Gain
during Speed
Search
%
100
100
100
100
100
100
100
100
b3-06
Speed
Estimation
Current Level
1
-
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
b3-08
Speed
Estimation
ACR P Gain
-
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
b3-26
Direction
Determination
Level
-
1000
1000
1000
1000
1000
1000
1000
1000
b8-03
Energy Saving
Filter Time
s
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
b8-04
Energy Saving
Coefficient
Value
-
265.7
245.8
245.8
189.5
189.5
145.38
145.38
140.88
C5-17
(C5-37)
Motor Inertia
kgm
2
0.0158
0.0158
0.0158
0.0255
0.026
0.037
0.037
0.053
C6-02
Carrier
Frequency
Selection
-
1
7
1
7
1
7
1
7
E2-01
(E4-01)
Motor Rated
Current (FLA)
A
5.7
7
7
9.8
9.8
13.3
13.3
19.9
E2-02
(E4-02)
Motor Rated
Slip
Hz
2.7
2.7
2.7
1.5
1.5
1.3
1.3
1.7
E2-03
(E4-03)
Motor No-
Load Current
A
1.9
2.3
2.3
2.6
2.6
4
4
5.6
E2-05
(E4-05)
Motor Line-to-
Line
Resistance
Ω
4.360
3.333
3.333
1.595
1.595
1.152
1.152
0.922
E2-06
(E4-06)
Motor
Leakage
Inductance
%
19
19.3
19.3
18.2
18.2
15.5
15.5
19.6
E2-10
(E4-10)
Motor Iron
Loss
W
105
130
130
193
193
263
263
385
E5-01
PM Motor
Code Selection
-
FFFF
FFFF
FFFF
FFFF
FFFF
FFFF
FFFF
FFFF
L2-02
Power Loss
Ride Through
Time
s
0.5
0.5
0.5
0.5
0.8
0.8
1
1
L2-03
Minimum
Baseblock
Time
s
0.5
0.6
0.6
0.7
0.7
0.8
0.8
0.9
L2-04
Powerloss V/f
Recovery
Ramp Time
s
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
L2-05
Undervoltage
Detection Lvl
(Uv1)
-
380
380
380
380
380
380
380
380
L3-24
Motor Accel
Time for
Inertia Cal
s
0.145
0.154
0.154
0.168
0.168
0.175
0.175
0.265
L8-02
Overheat
Alarm Level
°C
100
100
100
100
105
105
105
105
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIGA8002B GA800 Drive Programming...
Страница 14: ...i 2 Using the Product Safely 14 YASKAWA TOEPYAIGA8002B GA800 Drive Programming...
Страница 172: ...1 22 Parameters Changed by PM Motor Code Selection 172 YASKAWA TOEPYAIGA8002B GA800 Drive Programming...