SLFO → Set LFO parameter. With this you can change the settings of one of the 8 LFO.
The first digit from the left
X
xxx is the LFO number. The second digit x
X
xx is for which setting to be
changed: 0: Type, 1: Speed, 2: Amplitude. The last 2 digits xx
XX
are for the value of the setting.
SADD → Set modulation for the CV output 1..16 to
pure
or
add
setting. Here the 3
rd
digit from the
left xx
X
x defines the CV output number. The last digit xxx
X
defines if the modulator should be
added (Set to 1) to the current pitch or be pure (Set to 0)
PROW → Probability for the whole row except for the last FX column.
PCRD → Play Chord. Plays a chord on multiple CV outputs. x
X
xx selects the column and start CV
for the Basenote. For example, if set to 2xxx then the 2
nd
column is used for the basenote and the
selected CV for this column is also defined for the first note of the chord. All additional CV based
on this are used then for the Chord. For example, imagine a chord is selected with 4 notes. And the
column uses CV6. The Chord will be played then on CV6, CV7, CV8 and CV9. So the chord is not
related to the other columns. Even more, multiple chords can be played at the same time on one
step using more chord fx commands with other base-column selections.
Xx
XX
defines the selected chord (different chord use 2 to 6 notes). The following chords are
available: Minor 2
nd
, Major 2
nd
, Minor 3
rd
, Major 3
rd
, Perfect 4
th
, Diminished 5
th
/Tritone, Perfect 5
th
,
Minor 6
th
, Major 6
th
, Minor 7
th
, Major 7
th
, Triad Major, Triad Minor, Triad Diminished, Triad
Diminished 5
th
, Triad Diminished Augmented , Triad Suspended 4
th
, Triad Suspended 2
nd
, 7
th
Dominant, 7
th
Minor, 7
th
Major, 7
th
Minor Major, 7
th
Suspended, 7
th
Augmented, 7
th
Augmented Major,
7
th
Augmented 9
th
, 7
th
Half Diminished, 7
th
Diminished, 7
th
Diminished 5
th
, 7
th
Diminished Flat 9, 6
th
,
6
th
Minor, 9
th
, 9
th
Minor, 9
th
Major, 9
th
Diminished 5
th
, 11
th
PH 1 to PH8 → are placeholders for future FX and currently unused.
All further parameters are exactly the same as for the local
of the CV/Gate tracks
and so all functions of the local tracks can still be used. The only difference are the probability
settings which now belong to several CV outputs and FX.
The Probability settings are defined as the following:
CV1, CV2, CV3, CV4, CV5+6, FX1, FX2, FX3.
NerdSEQ – a tracker based Eurorack sequencer
Page 60
User Manual Revision V1.26 for Firmware V1.26
12 July 2022