time can be set up also in the Setup Screen. If a trigger is filled in on the same row, then the
auto-gate function is disabled for this row as the trigger will overrule.
You can pre-listen a note by using the
OK
button. (Works also in combination with
SHIFT
)
It is also possible to pre-listen your sequence by holding the
OK
button and scrolling
up/down. If a note value is filled in on the same step in the MOD column, then this note will
be updated as well. (Allows ‘duo-phonic’ pre-listen)
Also if the setting ‘Auto Fill in Trigger’ is enabled, then a trigger of 20ms is automatically
inserted when inserting a note. This is to get a fast result editing feeling when live
programming sequences.
Behind Note C-A there are 16 possible random ranges to select. The selections are marked
RN0 → RNF and with these a random note will play within the selected range. (Pressing
the
OK
button on a random command will bring you to the → Random Ranges screen.
There you can change the range.
Use
SHIFT+OK
on the note column to browse through different content:
C-0, C-4, C-8, RN0, ---, [ ]
•
Patch can select a patch which is executed before a note plays. A patch is kind of a macro
or a multifunction preset. It allows you to manipulate many FX functions at the same time
from every step. Press
OK
to create a new patch. Press
SHIFT + OK
on a filled in patch to
Clone the filled in patch into a new patch. SHIFT+DELETE will remove the patch from the
pattern field. (It will not delete/erase the patch. The same patch is still aligned and can be
used.) Enter the →
PATCH
button. More on patches in the
description.
•
Table allows to select a table to transpose notes or effects. Those have a different (or
same) time scale than the normal sequencer steps and can create nice arpeggio sounds or
fast or slow changing effects. (see →
to find out what tables are capable of).
A table number in the column will start the table and it can be stopped using the table stop
command in the same column below table 00 showing as the two asterisks ‘
**’.
Tables can
be entered using the table button. If a table is not initialized yet, then it will be either
automatically initialized by entering the table, or you can create a new table using the
OK
button. Initialized tables got the normal row colour, while uninitialized tables are ‘greyed out’
(have the colour of a muted track)
Pressing
SHIFT+OK
on a used table position will clone the selected table into a new one.
SHIFT+DELETE
will toggle between ‘
--
’ and ‘
**
’ .
NerdSEQ – a tracker based Eurorack sequencer
Page 23
User Manual Revision V1.26 for Firmware V1.26
12 July 2022