3. Loosen the Thumb Screw securing the
pump cover. Remove the cover.
4. With one hand secure the Brass Nut
then remove the plastic water inlet hose
connector. This should only be hand tight
5. Use the wrench to loosen the retaining
nut.
6. Pull off the plastic filter cover and the
screen.
1. Follow the proper procedure for High
Pressure Hose disconnection displayed
on the warning label. Then remove the
High Pressure Hose from the Pump
Box. Let the water drip dry.
2. Remove the Inlet Water Line. Press
in on the grey collar before pulling the
hose out. Let the water drip dry.
Procedure
9. Place the plastic cover over with
the metal end nut. Re-secure with the
wrench you have. Sealing here is all
achieved by o-rings, so be careful and
do not over-tighten.
10. Use one hand to hold the brass nut
and screw on the inlet hose connector.
11. Replace the Pump Box Cover,
tighten the Thumb Screws, reattach all
plumbing and electrical connections
and you are ready to resume cutting.
7. Clean off any debris off all surfaces. First
rinse off what you can then scrub off the
stubborn bits. The risk here is that a small
particle can be sucked through and get
stuck in the pump seals.
8. To re-assemble first place the screen
back on .
Maint
enan
ce |
SE
C
TION 7
120
121