Install WAZER
Estimated Time: 120 minutes
Requires two people.
Before your first Cut on the WAZER you will need to set up your machine. Here is what you will do:
•
Install the Pump Vent Cap
•
Establish three water connections
•
Install Inlet Water Filter and On/Off Valve
•
Establish three cable connections
•
Anchor WAZER to the wall
Install Pump Vent Cap
The Pump Box is shipped with a red Oil Cap that seals the oil chamber to ensure the Pump Box
does not leak oil during transport. This red Oil Cap must be replaced with the yellow Pump Vent
Cap prior to turning on the unit.
Running the unit with the red Oil Cap will damage the Pump Box, and this damage
WILL NOT be covered under warranty.
To install the Pump Vent Cap:
1. Loosen the four fasteners that hold the cover on. They will remain captured on the sheet
metal cover. You should be able to loosen these Pump Box Cover bolts with the tools
provided. Two are located along the back edge and two on the bottom front edge.
2. Remove the gray Pump Box cover by pulling the bottom front edge forward and top edge up.
3. Remove the red Oil Cap with the provided 17 mm wrench and replace it with the yellow Pump
Vent Cap found in the white box in the Setup Kit. Tighten the cap until it is finger tight and
retain the red oil cap for later shipping.
4. Replace the Pump Box cover and tighten the Pump Box Cover bolts so that the cover is
securely fastened. Ensure that they are well-secured in order to prevent unwanted vibration.
5. Visually inspect pressure release valve, make sure the tamper-proof mark in unbroken. If
found broken, please contact WAZER for assistance.
You will be required to replace the oil in the Pump Box every 300 hours of run time. For more
information, see Maintenance > Maintenance Procedures > Pump Box Oil Change.
To see the full required maintenance for the Pump Box, refer to Maintenance > Maintenance
Schedule.
VIDEO
DO NOT tilt the Pump Box backwards onto its water connections.
NEVER remove the Pump Box cover while the Pump Box is connected to power
or during operation.
Set
tin
g Up W
AZER |
SE
C
TION 4
34
35