AC 110
AC 110
Pump Box
Power
Pump Box
Signal
WAZER
Power
3
2
1
Power Cables
There are three electrical connections you need to make with WAZER:
1.
Establish the Pump Box Signal Connection
This is a cable that is permanently attached to WAZER Main Unit and needs to be connected
to the back of the Pump Box.
•
Untie the twist tie holding the Signal Cable to the back of WAZER.
NOTE: The WAZER Power Transformer wire is bundled with the Signal Cable. Set this aside
for later.
•
Unscrew the blue Cap on the Pump Box connector.
•
Line up white dots on the connector.
•
Insert the connector into the Pump Box and screw the blue Retention Ring on (finger tight is
sufficient.)
•
We suggest routing this wire along the High-Pressure Hose using zip ties.
2.
Connect the Pump Box Power Cable
The Pump Box comes with a protected Pump Box Power Cable. Attach this Pump Box Power
Cable to an appropriate wall receptacle given the model you have purchased and your home
setup. If you are connecting your 110 VAC 60hz WAZER (designated as V1.5A), make sure to
check if your wall breaker is 15amp or 20amp. As explained in the “Choosing a Location for
WAZER” section, if you only have 15amp circuits available to you make sure your pump unit is
on a different circuit from your main unit to avoid tripping your breaker.
•
When you plug in the Power Cable, you must press the RESET button on the GFCI/PRCD.
Look for a green light to turn on.
•
Press TEST button to ensure GFCI/PRCD functions properly. Then press RESET button to
re-start the GFCI/PRCD. We recommended to check this safety function every time WAZER is
turned on.
3.
Connect the WAZER Power Cable
WAZER runs on 24 VDC, which requires a Power Supply. You will find the Power Supply
adapter taped to WAZER; remove the Right-Side Access Panel for better access. The WAZER
Power Cable for the Power Supply can be found in the Accessory Kit.
•
WAZER has a current draw of 2 Amp. If you are in a 110VAC region and have the 110vac
Pump Box (V1.5A) plugged into a 15 Amp Circuit, you will need to run WAZER off an entirely
separate circuit. Make sure to plug the WAZER Power Cable into an outlet on another circuit.
•
If you are in a 110VAC region and have the 110vac Pump Box (V1.5A) plugged into a 20 Amp
Circuit, you can run WAZER and Pump Box off the same circuit.
•
If you are in a 220VAC region, the WAZER Main Unit and Pump Unit can be on the same
circuit provided the breaker is >11 amps.
•
Ensure that you place the Power Supply in a location free of drips and potential leaks from
WAZER.
DO NOT place the Power Supply under WAZER.
Find a good location on the tabletop
next to WAZER. Please do not put any other electric or electronic equipment under WAZER
•
In the event of a malfunction or breakdown, grounding provides a path of least resistance for
electric current to reduce the risk of electric shock. This tool is equipped with an electric cord
having an equipment-grounding conductor and a grounding plug. The plug must be plugged into
a matching outlet that is properly installed and grounded in accordance with all local codes and
ordinates.
•
If Power Supply cable or Pump Box cable is damaged or worn, stop installation or operation
IMMEDIATELY. Contact WAZER support to have it replaced.
•
Make sure the tool is connected to an outlet having the same configuration as the plug. No
adapter is available or should be used with this tool. If the tool must be reconnected for use
on a different type of electric circuit, the re-connection should be made by qualified service
personnel; and after re-connection, the tool should comply with all local codes and ordinances.
•
To reduce the risk of unintentional starting, make sure the WAZER main unit switch is in the off
position before plugging in. Make sure switch is in off position before plugging in.
*
Please double check to make sure the local power supply fit the model you have purchased,
before you plug WAZER in.
Set
tin
g Up W
AZER |
SE
C
TION 4
48
49