Base Module
Procedure
1. Disconnect the DigiVAC from the mains power supply.
2. Remove the L/H side cover from the base module.
3. Check the belt tension: There should be minimal slack, push the belt with
one finger, it should deflect by no more than 10mm.
4. Slacken the drive motor retaining nuts (see Figure 3:29 on page 43).
5. Using a suitable screwdriver as a lever, raise the motor assembly in it’s
adjustment slots and remove the drive belt from the pulley.
6. Tighten two diagonally opposed retaining nuts and check the tension.
Readjust if necessary.
7. Tighten the remaining retaining nuts, replace all covers and test.
3.6.11 Converting the DigiVAC from 50Hz to 60hz Supply Frequency
This procedure only applies to DigiVAC Base Modules prior to Serial No.
S0000150.
1. Disconnect the DigiVAC from the mains power supply.
2. Remove the L/H side panel from the base.
3. Remove the drive pulley fixing screw and washers.
Figure 3:30 Drive Pulley
4. Loosen the drive motor fixing nuts.
PARTS REQUIRED
TOOLS REQUIRED
None
3mm Allen Key
4mm Allen Key
13mm Spanner or Socket
PARTS REQUIRED
TOOLS REQUIRED
192-499 Pulley, HTD 25T-5M-15 Flanged
Only:
900-100 Zerox PCB
3mm Allen Key
5mm Allen Key
13mm Spanner or Socket
Screwdriver
Drive Pulley
Fixing Screw & Washers