Watkiss DigiVAC Service Manual - Issue 2 - 29/11/04
Trouble Shooting
•
8.2 Fuse Failure
FUSE
SYMPTOMS OF FAILURE
DigiVAC Standard
Mains input socket
No mains switch illumination
No mains switch illumination
Machine Dead
Machine Dead
DigiVAC Base PCB F1 Control Panel Dead
Control Panel Dead
Transformer LED on
Transformer LED on
Machine Dead
Machine Dead
DigiVAC Base PCB F2 Machine will start, but no
feed occurs showing up on
the bin as a Jam
‘PSU VOLTAGE ERROR: 28v’
message is displayed
No Jog or Oscillate Function
is available
DigiVAC Base Power
PCB F4
No Jog function
‘No Power to Stacker’ mes-
sage displayed
No Oscillate function selecta-
ble from the panel
XJOG Mimic shows yellow
DigiVAC Base Power
PCB F5
Motor Stalled Error
Motor Stalled Error
X-Jogger PCB F1
No Oscillate function
‘No Power to Stacker’ mes-
sage displayed
XJOG Mimic shows yellow
Transformer
Mains switch is illuminated
Mains switch is illuminated
LED on the transformer is
not illuminated
LED on the transformer is
not illuminated
Machine Dead
Machine Dead
8.3 SMD Inverter Error Codes
CODE
STATUS
CAUSE
REMEDY
OFF
Machine at rest
Motor not running
Start collator
50
Output frequency
Normal operation
N/A
CL
Current limit reached
(DigiVAC motor stalled)
Rated output current
exceeded
Check that input voltage not too
low
Mechanical jam in drive train
Check for physical jams
LU
Under Voltage in the DC
bus
Mains voltage too low
Check mains voltage
F1
EPM error
EPM missing or defective
Contact Watkiss Dealer