Trouble Shooting
•
Watkiss DigiVAC Service Manual - Issue 2 - 29/11/04
129
F2
F0 J
F
Internal error
N/A
Contact Watkiss dealer
0C1
Short circuit or overload Short circuit
Find reason for short circuit;
check motor cable
Internal fault in motor
Check motor
0C2
Earth fault
Grounded motor phase
Check motor/motor cable
0H
Controller over temper-
ature
Controller too hot inside
Ensure sufficient cooling to
inverter
0U
DC bus over voltage
Mains voltage too high
Check supply voltage
Earth leakage on motor side
Check motor/motor cable (sepa-
rate motor from controller)
CODE
STATUS
CAUSE
REMEDY