5.0 INSTALLATION AND FIXING
VL
2
VAL.130.--.M.EN Issue: A1
09.16
23
The inner nuts have no weight bearing function. They only serve to secure the valve when the downstream
device is removed.
(QVXUHSDUDOOHOWROHUDQFHRIWKHFRQQHFWLQJKRSSHUÀDQJHLVZLWKLQPP
Check and remove any possible vibrations of the plant, which could affect the safe and correct working of the
valve.
Ensure the valve is perfectly parallel after installation.
$YRLGFRQQHFWLRQRIVTXDUHYDOYHZLWKURXQGVLORÀDQJHRUURXQGYDOYHZLWKVTXDUHVLORÀDQJH
(QVXUHWKHUHLVQRSUHVVXUL]HGDLUSUHVHQWLQWKHYDOYHLQOHW]RQH)OXLGL¿FDWLRQV\VWHPKDVWREHDWOLVWFP
far from the inlet.
Follow strictly the assembly instruction given for actuators.
:LWKOXPS\JUDQXODUDQG¿EURXVPDWHULDOVXVHDVWHHOEODGH
With raised product columns it is recommended to insert a safety cup in the silo, above the valve.
&ORVHWKHYDOYHRQO\ZKHQPDWHULDOLVÀRZLQJ9DOYHVPXVW127RSHUDWHLQDEVHQFHRIPDWHULDO
Clean the valve regularly with either air or water. This is particularly important if the material handled tends to
compact or to solidify due to long shut-down periods.
Do not insert any type of gasket between the silo
À
ange and the upper
À
ange of the side valve!