Type of parameter with option to select only one setting option (alternative).
EXAMPLE:
MENU \ SETTINGS \ COMMANDS \ FREQUENCY SETPOINT \
... \ SETTINGS \ FUNCTIONS \ LOGICAL BLOCKS\ LB1 (Fast) \
One setting option selection of selection type parameter examples
Parameter type with a option to select multiple possible value elections, modes, respectively active
bit of parameter.
Parameter type: SELECTION
Name [ID]
Description
Def.
Start source
[194]
Setting the converter start source. The START command generates the desired voltage and frequency
on the U,V,W outputs (or U,V for a single phase load).
BIN1
Control panel Pressing the green START button on the control panel causes the converter to start. The start is canceled by
pressing the red STOP button.
Permanent
start
The converter starts immediately after the switch on.
BIN1 The converter start after the activation of the 1st binary input.
BIN5 The converter starts after the activation of the 5th binary input.
BIN6 The converter starts after the activation of the 6th binary input.
MODBUS The converter start is controlled over the serial communication. See the MODBUS serial communication
protocol.
PROFIBUS The converter start is controlled over the serial communication. See the PROFIBUS serial communication
protocol.
Special
The converter start is controlled by a special preset signal and switching thresholds, see P[987] SPECIAL
START.
MENU \ SETTINGS \ COMMANDS \ START STOP RESET \
Basic information about type of parameter - selection
The name of specific (alternative)
selection of parameter value
Additional information about the meaning
of a specific parameter selection
Parameter type: MULTIPLE SELECTION (MASK)
Name [ID]
Description
Def.
V/f Type [347]
V/f Curve type. Selecting the features of the V/f control method operation.
□ IR compensation
Turns on the stator resistance loss compensation P[973] Compensation of IR
(CIR). Requires correct value of the motor parameters and the stator resistance
P[345] Stator resistance.
□ ST controller
Turns on the starting torque controller P[29] ST Controller (STC) to boost starting
torque.
* When the square is black ■ - the default setting is set
MENU \ SETTINGS \ CONTROL AND REGULATION \ V/f CONTROL \ V/f CURVE \
Basic information about the
parameter type - multiple selection
Names of parameter
value elections (modes)
Additional information about the meaning of
individual parameter elections (modes)