Parameters PROFIBUS
Group of parameters number [1176]
MENU \ SETTINGS \ COMMUNICATION \ PROFIBUS \ PARAMETERS PROFIBUS
Name [ID]
Description
Def.
APD
1
[1168]
[515] Current INV
Signal
APD
2
[1169]
[593]
Inst.
production
Signal
APD
3
[1170]
-
Signal
APD
4
[1171]
-
Signal
Dig.
1
[1172]
Determining the last transferred digit from the left.
-
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -
Dig.
2
[1173]
The magnitude of 10 that determines the last transferred digit from the left. (...,
1 tens, 0 ones, -1 tenths, ..).
-
Look choises of parameter's Dig. 1 [1172] (page 84)
Dig.
3
[1174]
The magnitude of 10 that determines the last transferred digit from the left. (...,
1 tens, 0 ones, -1 tenths, ..).
-
Look choises of parameter's Dig. 1 [1172] (page 84)
Dig.
4
[1175]
The magnitude of 10 that determines the last transferred digit from the left. (...,
1 tens, 0 ones, -1 tenths, ..).
-
Look choises of parameter's Dig. 1 [1172] (page 84)
7.10 PAR. SETS
Group of parameters number [206]
Selecting a set of parameters for the inverter operation.
MENU \ SETTINGS \ PAR. SETS
Name [ID]
Description
Def.
Set
switching
[591]
Setting the way of switching between the sets.
Combined
Combined
Only the first 2 bits of the binary switch are used. Output set corresponds to the binary
combination of these bits. If no bits are active, the 1st set is active. If only 1 bit is active, the
2nd set is active. and so on.
Single
Every single bit of the binary switch represents one set (bit 1 represents set 2). If more
switches are active, the set with the higher sequence number is active. If no binary switch is
active, the 1st set is active.
Parameter
It is possible to set the active set using the Active set [205] (page 84) parameter.
Active
set
[205]
Switches the active set of parameters, from which the inverter will take its
configuration.
Set 1
Set 1
Inverter will take its configuration from 1st set of parameters.
Set 2
Inverter will take its configuration from 2nd set of parameters.
Set 3
Inverter will take its configuration from 3rd set of parameters.
Set 4
Inverter will take its configuration from 4th set of parameters.
7.10.1 SET SWITCH
Group of parameters number [269]
Binary set switch setting.