W44-Reserved
Reserved
W45-Reserved
Reserved
W46-Reserved
Reserved
F47-Set
switching
Switching to another set is activated. If the message persists, it is not possible to switch
the sets (Some parameters can only be changed during stop). For the duration of the
warning, the value of [269] (page 84) is displayed in FAULTS window.
F48-Restore
point
Restore point for restoring the inverter settings is being created.
W49-External
warning
External warning signal is active. Source of the warning is configured in the parameter
Ext. warning signal [838] (page 79).
W50-CPU
Overload
Excessive overload of the inverter control processor. Control quality decreases when this
warning occurs. It is recommended to decrease the inverter switching frequency
Switching frequency [6] (page 37). For the duration of the warning, the value of load of
the 10ms interrupt is displayed in FAULTS window.
F51-Initialization
During the initialization Initialization time [981] (page 37) the inverter ignores control
commands. It is used for slower superior systems.
W52-DC voltage
limit
DC current limitiing by DC voltage saturation during Idc regulation.
W53-Reserved
Reserved
W54-Reserved
Reserved
W55-Wait
for
STOP
Waiting for the STOP command. Due to safety reasons, STOP command has to come
prior to the START command to start the drive.