MENU \ SETTINGS \ FUNCTIONS \ PLC FUNCTIONS \ LOGICAL BLOCKS \ LB1 (FAST)
Name [ID]
Description
Def.
LB1 Operation
[543]
Logical operation type that will be used for the logical block.
OR
OR
Disjunction operation. The output is active if at least one of the inputs is active.
AND
Conjunction operation. Output is active if both inputs are active.
XOR
Exclusive sum operation. Output is active if inputs are different (one active, the other
inactive).
RS
RS flip-flop. Output is set to inactive if the first input is active. Output is set to active if the
second input is active.
=
Operation equals. Output is active if both inputs are identical.
>=
Operation greater or equal. Output is active if the first signal is greater than or equals the
second signal.
>
Operation greater. Output is active if the first signal is greater than the second signal.
LB1 Level [889]
Input and output type of the logical block.
□
Output
negated.
Logical block output will be negated.
□
Input
1
negated.
First input signal is negated.
□
Input
2
negated.
Second input signal is negated.
□ Input 1 edge. First LB input responds to the leading edge of the signal.
□ Input 2 edge. Second LB input responds to the leading edge of the signal.
LB1_1
Signal
[100]
Signal selection for the 1st input of LB1. It will be processed according to the selected
operation. Either numeric or discrete signal can be chosen.
-
Signal
LB1_1 switch on
[107]
Conditions for switching on the LB1_1.
-
- ÷ -
LB1_1
switch
off [108]
LB1_1 switch off: In case of a numeric signal if the signal value is lower than the
defined level.
-
- ÷ -
LB1_2
Signal
[110]
Signal selection for the 2nd input of LB1. It will be processed according to the
selected operation. Either numeric or discrete signal can be chosen.
-
Signal
LB1_2 switch on
[111]
Conditions for switching on the LB2.
-
- ÷ -
LB1_2
switch
off [112]
LB1_2 switch off: In case of a numeric signal if the signal value is lower than the
defined level.
-
- ÷ -
LB2 (Fast)
Group of parameters number [167]
Second quick logical operation setting (1ms reaction time).
MENU \ SETTINGS \ FUNCTIONS \ PLC FUNCTIONS \ LOGICAL BLOCKS \ LB2 (FAST)
Name [ID]
Description
Def.
LB2 Operation
[544]
Logical operation type that will be used for the logical block. Configuration possibilities
are the same as in LB 1 LB1 Operation [543] (page 59).
OR
Look choises of parameter's LB1 Operation [543] (page 59)
LB2 Level [890]
Input and output type of the logical block. Configuration possibilities are the same as
in LB 1 LB1 Level [889] (page 59).
Look choises of parameter's LB1 Level [889] (page 59)
LB2_1
Signal
[113]
Signal selection for the 1st input of LB2. It will be processed according to the selected
operation. Either numeric or discrete signal can be chosen.
-