RU , GSE, FOTO CONTROL, QUATROFREM v.2.53x
15. apríla 2019
Page 22 from 97
Name [ID]
Description
Dim.
■ BIN1
State of 1st binary input (Terminal 1).
■ BIN2
State of 2nd binary input (Terminal 2).
□ BIN3
State of 3rd binary input (Terminal 3).
□ BIN4
State of 4th binary input (Terminal 4).
□ BIN5
State of 5th binary input (Terminal 5).
□ BIN6
State of 6th binary input (Terminal 6).
4.5.2 AIN
Group of parameters number [82]
Diagnostic group of quantities for the analog inputs of the inverter AIN1 to AIN4.
Parameters of the analog inputs can be configured in the parameter group [144] (page 49).
MENU \ DIAGNOSTICS \ INPUTS AND OUTPUTS \ AIN
Name
[ID]
Description
Dim.
AIN1
[319]
Value of the signal brought to the analog input terminals X1:11 and - X1:12 in physical units.
Using the parameter AIN1 Signal [331] (page 50) select the quantity that will be changed
according to the analog input level change.
Parameters of the analog input can be configured in the parameter group [147] (page 49).
V
AIN2
[320]
Value of the signal brought to the analog input terminals X1:13 and - X1:14 in physical units.
Using the parameter AIN2 Signal [337] (page 51) select the quantity that will be changed
according to the analog input level change.
Parameters of the analog input can be configured in the parameter group [329] (page 50).
V
AIN3
[321]
Value of the signal brought to the analog input terminals X1:15 and - X1:16 in physical units.
Using the parameter AIN3 Signal [343] (page 52) select the quantity that will be changed
according to the analog input level change. Not available for the UNIFREM 400 M converters.
Parameters of the analog input can be configured in the parameter group [148] (page 51).
V
AIN4
[322]
Value of the signal brought to the analog input terminals X1:17 and - X1:18 in physical units.
Using the parameter AIN4 Signal [349] (page 53) select the quantity that will be changed
according to the analog input level change. Not available for the 400 M converters.
Parameters of the analog input can be configured in the parameter group [152] (page 52).
V
AIN1
Rel.
[315]
Relative value of the signal connected to the analog input ter X1:11 and - X1:12.
Parameters of the analog input can be configured in the parameter group [147] (page 49).
%
AIN2
Rel.
[316]
Relative value of the signal connected to the analog input ter X1:13 and - X1:14.
Parameters of the analog input can be configured in the parameter group [329] (page 50).
%
AIN3
Rel.
[317]
Relative value of the signal connected to the analog input ter X1:15 and - X1:16.
Parameters of the analog input can be configured in the parameter group [148] (page 51).
%
AIN4
Rel.
[318]
Relative value of the signal connected to the analog input ter X1:17 and - X1:18.
Parameters of the analog input can be configured in the parameter group [152] (page 52).
%
4.5.3 RELAYS
Group of parameters number [50]
MENU \ DIAGNOSTICS \ INPUTS AND OUTPUTS \ RELAYS
Name [ID]
Description
Dim.
Relay [185]
Condition of the output relays. Filled rectangle represents the RELEx physical switch on.
■ RELAY1
Condition of the 1st output relay.
■ RELAY2 Condition of the 2nd output relay.
□ RELAY3 Condition of the 3rd output relay.
4.5.4 AOUT
Group of parameters number [641]
Diagnostic group of quantities for the analog inputs of the inverter AOUT1 to AOUT3.