RU , GSE, FOTO CONTROL, QUATROFREM v.2.53x
15. apríla 2019
Page 63 from 97
Name [ID]
Description
Def.
LB7_2 switch on
[535]
Conditions for switching on the LB7_2.
-
- ÷ -
LB7_2
switch
off [536]
LB7_2 switch off: In case of a numeric signal if the signal value is lower than the
defined level.
-
- ÷ -
LB8
Group of parameters number [171]
Eight logical operation setting.
MENU \ SETTINGS \ FUNCTIONS \ PLC FUNCTIONS \ LOGICAL BLOCKS \ LB8
Name [ID]
Description
Def.
LB8 Operation
[550]
Logical operation type that will be used for the logical block. Configuration possibilities
are the same as in LB 1 LB1 Operation [543] (page 59).
OR
Look choises of parameter's LB1 Operation [543] (page 59)
LB8 Level [896]
Input and output type of the logical block. Configuration possibilities are the same as
in LB 1 LB1 Level [889] (page 59).
Look choises of parameter's LB1 Level [889] (page 59)
LB8_1
Signal
[537]
Signal selection for the 1st input of LB8. It will be processed according to the selected
operation. Either numeric or discrete signal can be chosen.
-
Signal
LB8_1 switch on
[538]
Conditions for switching on the LB8_1.
-
- ÷ -
LB8_1
switch
off [539]
LB8_1 switching off: In case of a numeric signal if the signal value is lower than the
defined level.
-
- ÷ -
LB8_2
Signal
[540]
Signal selection for the 2nd input of LB8. It will be processed according to the
selected operation. Either numeric or discrete signal can be chosen.
-
Signal
LB8_2 switch on
[541]
Conditions for switching on the LB8_2.
-
- ÷ -
LB8_2
switch
off [542]
LB8_2 switch off: In case of a numeric signal if the signal value is lower than the
defined level.
-
- ÷ -
NUMERICAL BLOCKS
Group of parameters number [87]
Creating computational links among signals. They react with a sampling time of 10 ms.
NB1
Group of parameters number [469]
Settings of the first numerical block.
MENU \ SETTINGS \ FUNCTIONS \ PLC FUNCTIONS \ NUMERICAL BLOCKS \ NB1
Name [ID]
Description
Def.
NB1 input 1
[897]
Selection of signal for the 1st input of NB1. This signal will be processed
according the selected operation.
-
Signal
NB1 input 2
[898]
Selection of signal for the 2nd input of NB1. This signal will be processed
according the selected operation.
-
Signal