![Vonsch FOTO CONTROL Series Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/vonsch/foto-control-series/foto-control-series_configuration-and-diagnostics_1049783017.webp)
RU , GSE, FOTO CONTROL, QUATROFREM v.2.53x
15. apríla 2019
Page 17 from 97
Name [ID]
Description
Dim.
String26 [1096]
Energy supplied by the photovoltaic string today.
kWh
String27 [1097]
Energy supplied by the photovoltaic string today.
kWh
String28 [1098]
Energy supplied by the photovoltaic string today.
kWh
String29 [1099]
Energy supplied by the photovoltaic string today.
kWh
String30 [1100]
Energy supplied by the photovoltaic string today.
kWh
String31 [1101]
Energy supplied by the photovoltaic string today.
kWh
String32 [1102]
Energy supplied by the photovoltaic string today.
kWh
4.2 Power and energy
Group of parameters number [511]
Quantities for evaluation the power and energy consumed or produced. These quantities do not replace
official electricity meters, but they offer an insight and check of produced and consumed energy by the
device.
MENU \ DIAGNOSTICS \ POWER AND ENERGY
Name [ID]
Description
Dim.
Inst. consumption
[592]
Instantaneous value of consumed power (from the grid to the inverter).
W
Inst.
production
[593]
Instantaneous value of produced power (from the inverter to the grid).
W
Active grid power
[70]
Instantaneous active power transfered to L1,L2,L3 phases of the grid. Positive
values represent energy consumption, negative represent energy production.
W
Reactive
grid
power [1196]
Instantaneous reactive power of the inverter on the Grid side of LCL filter. Positive
values represent the capacitive nature, negative values represent the inductive
nature of power.
VAr
Active inv. power
[66]
Active power of the inverter measured on IGBT elements. Positive values
represent energy consumption, negative represent energy production.
W
Reactive
inv.
power [222]
Instantaneous reactive power of the inverter on the inverter side of LCL filter.
Positive values represent the capacitive nature, negative values represent the
inductive nature of power.
VAr
4.2.1 Production stats
Group of parameters number [640]
Overview of daily, weekly, monthly and annual production of energy.
MENU \ DIAGNOSTICS \ POWER AND ENERGY \ PRODUCTION STATS
Name [ID]
Description
Dim.
Today [594]
Produced energy for present day.
kWh
Yesterday [595]
Produced energy for yesterday.
kWh
2cdays ago [596]
Produced energy for the day before yesterday.
kWh
This week [597]
Produced energy for this week.
kWh
Last week [598]
Produced energy for the last week.
kWh
This month [599]
Produced energy for this month.
kWh
Last month [600]
Produced energy for the last month.
kWh
This year [601]
Produced energy for this year.
kWh
Last year [602]
Produced energy for the last year.
kWh
Total [677]
Total produced energy since the last reset.
kWh
Last reset [678]
Date of last reset of produced energy counters.
4.2.2 Energy meter
Group of parameters number [567]
Information about consumed and produced energy.
MENU \ DIAGNOSTICS \ POWER AND ENERGY \ ENERGY METER