Serial Interface Manual
TLS4/TLS-450 Monitoring Systems
Part No. 577013-950, Revision L
580
Function Code:
B11
Version 1
Function Type:
Groundwater Sensor Diagnostic Report
Command Format:
Display:
<SOH>IB11SS
Computer:
<SOH>iB11SS
Typical Response Message, Display Format:
<SOH>
IB11SS
JAN 28, 1995 10:16 AM
SENSOR DIAGNOSTIC – GROUNDWATER SENSOR INFORMATION REPORT
SINGLE SENSOR
SAMPLE
SENSOR COUNTER VALUE 1 VALUE 2 STATUS
1 5 49875 90972 OUT ALARM
<ETX>
Typical Response Message, Computer Format:
<SOH>iB11SSYYMMDDHHmmSSNNFFFFFFFF...
SSNNFFFFFFFF&&CCCC<ETX>
Notes:
1.
YYMMDDHHmm - Current Date and Time
2.
SS - Sensor Number (Decimal, 00=all)
3.
NN - Number of eight character Data Fields to follow (Hex)
4.
FFFFFFFF - ASCII Hex IEEE float:
1. Sample counter
2. High Reference Channel
3. Low Reference Channel
4. Hydrocarbon Channel Last Reading
5. Hydrocarbon Channel Average Reading
6. Water Channel Last Reading
7. Water Channel Average Reading
5.
&& - Data Termination Flag
6.
CCCC - Message Checksum