Serial Interface Manual
TLS4/TLS-450 Monitoring Systems
Part No. 577013-950, Revision L
294
Function Code:
612
Version 1
Function Type:
Set Tank SIPHON Manifolded Partners
Command Format:
Inquire:
Display:
<SOH>S612TTtt…TTtt
<SOH>I612TT
Computer:
<SOH>s612TTtt…TTtt
<SOH>i612TT
Typical Response Message, Display Format:
<SOH>
I612TT
JAN 22, 2002 3:17 PM
TANK MANIFOLDED PARTNERS
TANK LABEL
SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS
2 REGULAR UNLEADED 1 3
<ETX>
Typical Response Message, Computer Format:
<SOH>i612TTYYMMDDHHmmTTNNtt...
TTNNtt&&CCCC<ETX>
Notes:
1.
YYMMDDHHmm - Current Date and Time
2.
TT - Number of the first tank to be SIPHON manifolded
3.
NN - Number of tanks that are SIPHON manifolded together
4.
tt - Tank numbers of other tanks to be SIPHON manifolded to first
tank
5.
&& - Data Termination Flag
6.