Serial Interface Manual
TLS4/TLS-450 Monitoring Systems
Part No. 577013-950, Revision L
566
Function Code A66 Notes:
(Continued)
Typical Response Message, Computer Format:
<SOH>iA66TTYYMMDDHHmmTTpRRRRYYMMDDHHmmFFNNEEEEEEEESSSSSSSSVVVVVVVVTTTTTTTT...
TTpRRRRYYMMDDHHmmFFNNEEEEEEEESSSSSSSSVVVVVVVV
TTTTTTTT&&CCCC<ETX>
Notes:
1.
YYMMDDHHmm - Current Date and Time
2.
TT - Tank Number (Decimal, 00=All Tanks)
3.
p – Product Code (ASCII character [20h-7Eh])
4.
RRRR – Number of Records to follow (ASCII hex)
5.
YYMMDDHHmm – Record Date and Time stamp
6.
FF – Status Flag (Hex)
00=Data Used
01=Not mapped
02=Time Set Back
03=Gap Too Long
04=Delivery
05=Temp Low
06=Temp High
07=Temp Increase
08=Volume High
09=Volume Low
0A=Volume Change
0B=Not Calibrated
0C=Cal Time Filter
0D=No Sales Data
0E=Temp Decrease
0F=Reset Filter
10=Therm Flag
11=DIM Reset
12=BDIM Transaction
7.
NN - Number of eight character data fields to follow (Hex
8.
EEEEEEEE – Ending Volume (ASCII Hex IEEE float)
9.
SSSSSSSS – Sales (ASCII Hex IEEE float)
10.
VVVVVVVV - Hourly Variance (ASCII Hex IEEE float)
11.
TTTTTTTT - Ending Temperature (ASCII Hex IEEE float)
12.
&& - Data Termination Flag
13.