Serial Interface Manual
TLS4/TLS-450 Monitoring Systems
Part No. 577013-950, Revision L
546
Function Code A18 Notes:
(Continued)
COUNTS 17 : 017460
COUNTS 18 : 044370
OPTIONS CODE : 0X0000
<ETX>
Typical Response Message, Computer Format:
<SOH>iA18TTYYMMDDHHmmTTppppsssssszzzzllllllllggggggggSSSSSSSS
rrrrrrruuuuuuuuYYMMDDhhhhhhhhYYMMDDkkkkkkkk
AAaaaaaaaa...aaaaaaaaBBbbbbbbbb...bbbbbbbb
NNcccccccc...ccccccccKKKKKKKK
TTppppsssssszzzzllllllllggggggggSSSSSSSS
rrrrrrruuuuuuuuYYMMDDhhhhhhhhYYMMDDkkkkkkkk
AAaaaaaaaa...aaaaaaaaBBbbbbbbbb...bbbbbbbb
NNcccccccc...ccccccccKKKKKKK&&CCCC<ETX>
Notes:
1.
YYMMDDHHmm - Current Date and Time
2.
TT - Tank Number (Decimal, 00=all)
3.
pppp - Probe Type (Hex)
4.
ssssss - Serial Number (Decimal)
5.
zzzz - Probe ID (Hex)
6.
llllllll - Probe Length (ASCII Hex IEEE float)
7.
gggggggg - Gradient (ASCII Hex IEEE float)
8.
SSSSSSSS - Number of Samples (Hex)
9.
rrrrrrrr - Samples Read (Hex)
10.
uuuuuuuu - Samples Used (Hex)
11.
YYMMDD - Original Reference Distance Date
12.
hhhhhhhh - Original Reference Distance Value (ASCII Hex IEEE float)
13.
YYMMDD - Current Reference Distance Date
14.
kkkkkkkk - Current Reference Distance Value (ASCII Hex IEEE float)
15.
AA - # of 8-Byte Temperature Sensor Values to Follow (Hex)
16.
aaaaaaaa - Temperature Sensor Values (ASCII Hex IEEE float)
17.
BB - # of 8-Byte Temperature Sensor Difference Values to Follow
(Hex)
18.
bbbbbbbb - Temperature Sensor Difference Values (ASCII Hex IEEE float)
19.
NN - # of 8-Byte Channel Count Values to Follow (Hex)
20.
cccccccc - Channel Count Values (ASCII Hex IEEE float)
21.
KKKKKKKK - Probe Options Code (ASCII-Hex unsigned long)
0=Standard Temperature Probe
1=Low Temperature Probe
22.
&& - Data Termination Flag
23.
CCCC - Message Checksum