Serial Interface Manual
TLS4/TLS-450 Monitoring Systems
Part No. 577013-950, Revision L
366
Function Code:
708
Version 1
Function Type:
Set Vapor Sensor Alarm Threshold
Command Format:
Inquire:
Display:
<SOH>S708SSVVVVVV
<SOH>I708SS
Computer:
<SOH>s708SSFFFFFFFF
<SOH>i708SS
Notes:
1.
SS - Vapor Sensor Number (Decimal, 00=all)
2.
VVVVVV - Vapor alarm threshold (Decimal)
3.
FFFFFFFF - Vapor alarm threshold (ASCII Hex IEEE float)
Typical Response Message, Display Format:
<SOH>
I708SS
JAN 28, 1995 10:41 AM
VAPOR ALARM THRESHOLD
SENSOR LOCATION THRESHOLD
1 VAPOR SENSOR #1 100000
<ETX>
Typical Response Message, Computer Format:
<SOH>i708SSYYMMDDHHmmSSFFFFFFFF...
SSFFFFFFFF&&CCCC<ETX>
Notes:
1.
YYMMDDHHmm - Current Date and Time
2.
SS - Vapor Sensor Number (Decimal, 00=all)
3.
FFFFFFFF - Vapor alarm threshold (ASCII Hex IEEE float)
4.
&& - Data Termination Flag
5.