Serial Interface Manual
TLS4/TLS-450 Monitoring Systems
Part No. 577013-950, Revision L
345
Function Code:
6A4
Version 1
Function Type:
Set Tank 1 Point Full Height Volume for Tall Tanks
Command Format:
Inquire:
Display:
<SOH>S6A4TTGGGGGGGGGGGG
<SOH>I6A4TT
Computer:
<SOH>s6A4TTFFFFFFFF
<SOH>i6A4TT
Notes:
1.
TT - Tank Number (Decimal, 00=all)
2.
GGGGGGGGGGGG - Full Height Volume, Gallons (Decimal)
3.
FFFFFFFF - Full Height Volume, Gallons (ASCII Hex IEEE float)
Typical Response Message, Display Format:
<SOH>
I6A4TT
JAN 22, 1996 3:16 PM
TANK FULL VOLUME
TANK LABEL
GALLONS
1 REGULAR UNLEADED 9728
<ETX>
Typical Response Message, Computer Format:
<SOH>i6A4TTYYMMDDHHmmTTFFFFFFFF...
TTFFFFFFFF&&CCCC<ETX>
Notes:
1.
YYMMDDHHmm - Current Date and Time
2.
TT - Tank Number (Decimal, 00=all)
3.
FFFFFFFF - Full Height Volume, Gallons (ASCII Hex IEEE float)
4.
&& - Data Termination Flag
5.
CCCC - Message Checksum