Serial Interface Manual
TLS4/TLS-450 Monitoring Systems
Part No. 577013-950, Revision L
335
Function Code 63E Notes:
(Continued)
The following 4 fields marked with an asterisk are only present if Tank Chart Security
is enabled.
5.
cccccccc - * Tank Capacity, Gallons (ASCII Hex IEEE float)
6.
x…x - * Console Serial Number (20 ASCII characters [20h-7Eh])
7.
yyyyyy - * Probe Serial Number (Decimal)
8.
z…z - * Weights and Measures Office (20 ASCII characters [20h-
7Eh])
9.
dddddddd - Tank Diameter, Inches (ASCII Hex IEEE float)
10.
ffffffff - Full Volume, Gallons (ASCII Hex IEEE float)
11.
nnnn - Number of Height/Volume Pairs (Hex)
12.
HHHHHHHH - Height, Inches (ASCII Hex IEEE float)
13.
VVVVVVVV - Volume, Gallons (ASCII Hex IEEE float)
14.
&& - Data Termination Flag
15.
CCC - Message Checksum