Serial Interface Manual
TLS4/TLS-450 Monitoring Systems
Part No. 577013-950, Revision L
320
Function Code:
62C
Version 1
Function Type:
Set Tank Periodic Test Type
Command Format:
Inquire:
Display:
<SOH>S62CTTp
<SOH>I62CTT
Computer:
<SOH>s62CTTp
<SOH>i62CTT
Typical Response Message, Display Format:
<SOH>
I62CTT
JAN 22, 1996 3:19 PM
TANK PERIODIC TEST TYPE
TANK LABEL
PERIODIC TEST TYPE
1 REGULAR UNLEADED QUICK
<ETX>
Typical Response Message, Computer Format:
<SOH>i62CTTYYMMDDHHmmTTp...
TTp&&CCCC<ETX>
Notes:
1.
YYMMDDHHmm - Current Date and Time
2.
TT - Tank Number (Decimal, 00=all)
3.
p - Periodic Test Type:
0=Standard Test
1=Quick Test (only MAG Probes may be set to QUICK)
4.
&& - Data Termination Flag
5.
CCCC - Message Checksum