Page 14
T47541109 Rev. J
FlexJet Head Assembly
TECHNICAL
PUBLICATIONS
This Document Supports Assembly 47541109 Rev. F
Calibration Table
The following table lists maintenance procedures which require calibrations
after completing the maintenance. Refer to the Calibration, CPE, and
Measurement manual when performing the calibrations required to help
ensure that the component placements are within specifications. (CPE means
Calibration Placement Enhancement.)
Maintenance Procedure
Calibrations Required After Maintenance
Installing a FlexJet Head
• Perform Machine Calibration and Calibration Placement
Enhancement (CPE) for a new head installation.
• Perform CPE for an installation to the previous location of the
head.
Replacing/Aligning a Coupler Body
CPE
Adjusting the Spindle Drive Belt Tension
Spindle Height Calibration and CPE
Setting the Touch-Down Sensors
Spindle Height Calibration
Cleaning the Pin Mirrors
Spindle Height Calibration
Comprehensive Head Maintenance
Spindle Height Calibration, Mirror Calibration, and CPE
Replacing the Stop Brake Belt
CPE
Replacing the Z Stop Brake Assembly
CPE
Replacing a Spindle Touch-Down Sensor
Spindle Height Calibration and CPE
Replacing a Spindle Assembly
Machine Calibration and CPE
Replacing a Clutch
Spindle Height Calibration, Mirror Calibration, and CPE
Replacing a Fiber Optic Cable
Spindle Height Calibration
Replacing a Spindle Drive Belt
Spindle Height Calibration and CPE