Page 26
T47541109 Rev. J
FlexJet Head Assembly
TECHNICAL
PUBLICATIONS
This Document Supports Assembly 47541109 Rev. F
3.
Remove feeders that are obstructing the work.
The machine cover must remain open during this procedure to place the
Interlock circuit in the violated state, disabling machine servo axes.
Failure to comply could result in serious personal injury.
4.
Remove the safety cover below the hinged cover and open the hinged
cover to access the FlexJet Head.
5.
Remove the FlexJet Head Cover.
Install the Vacuum Gauge
1.
Remove the nozzle from Spindle 1.
2.
If the vacuum gauge has an adapter designed to fit inside the Coupler
Body, push the adapter into the bottom of the selected spindle.
3.
If the vacuum gauge does not have an adapter designed to fit inside the
Coupler Body, install a 10MPF nozzle in the spindle. Then install the
gauge on the 10MPF nozzle.
4.
Continue with the Measure the Vacuum Level section.
Measure the Vacuum Level
1.
Select
Machine Status > Diagnostics > Discrete I/O > Head
The Discrete I/O - Head Subsystem I/O dialog box displays.
2.
Select the correct
Head #
(number) option button.