![UIC GSM FlexJet Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/uic/gsm-flexjet/gsm-flexjet_manual_3277471035.webp)
Page 30
T47541109 Rev. J
FlexJet Head Assembly
TECHNICAL
PUBLICATIONS
This Document Supports Assembly 47541109 Rev. F
The Discrete I/O - Head Subsystem I/O dialog box displays.
5.
Select the correct
Head #
(number) option button.
6.
Perform the following steps to enable air kiss on the spindles.
a.
Select the
Tool #
. Begin with tool number 1.
b.
Highlight
AIR_KISS
and
MAIN_VACUUM_CONTROL
in the
Select Outputs
field.
c.
Select
Set Outputs
.
d.
Repeat steps 6a to 6c until air kiss is on for all 7 spindles.
7.
Remove feeders that are obstructing the work.
The machine cover must remain open during this procedure to place the
Interlock circuit in the violated state, disabling machine servo axes.
Failure to comply could result in serious personal injury.
8.
Open the hinged cover and remove the safety cover below the hinged
cover.
Check the Air Kiss
1.
Verify that all 7 spindles are emitting air from the bottom of the
Coupler Bodies. If a spindle is not emitting air, check the hoses on the
Coupler Body Assemblies and the Manifold to verify that the hoses are
properly seated. Reseat any hoses that are loose and replace any hoses
that are damaged. If air kiss is still not present, contact a Universal
Instruments Technical Specialist.