Appendix E
Serial Attached SCSI BIOS Configuration Utility
187
View Array Screen
The View Array screen allows you to view the current array configuration, as shown
in
FIGURE E-16
. Press Alt+N to view the next array. Press C to create a new array.
TABLE E-12
describes the fields of the screen.
********************************************************************************
* LSI Logic MPT Setup Utility v6.02.00.00 (2005.07.08) *
* View Array -- SAS1064 *
* Array 1 of 1 *
* Identifier LSILOGICLogical Volume 3000 *
* Type IM *
* Scan Order 2 *
* Size(MB) 69618 *
* Status Optimal *
* *
* Manage Array *
* *
* Scan Device Identifier RAID Hot Drive Pred Size *
* ID Disk Spr Status Fail (MB) *
* 3 FUJITSU MAV2073RCSUN72G 0301 Yes No Secondary No 69618 *
* 4 FUJITSU MAV2073RCSUN72G 0301 Yes No Primary No 69618 *
* *
* *
* *
* *
* *
* *
* Esc = Exit Menu F1/Shift+1 = Help *
* Enter=Select Item Alt+N=Next Array C=Create an array *
*******************************************************************************
FIGURE E-16
View Array Screen
TABLE E-12
View Array Screen Field Descriptions
Field
Description
Array
The number of the array.
Identifier
The identifier of the array.
Type
The RAID type of the array.
Scan Order
The scan order of the array.
Size(MB)
The size of the array.
Status
The status of the array.
Содержание Netra X4200 M2
Страница 10: ...x Netra X4200 M2 Server Service Manual May 2007...
Страница 14: ...xiv Netra X4200 M2 Server Service Manual May 2007...
Страница 24: ...10 Netra X4200 M2 Server Service Manual May 2007...
Страница 46: ...32 Netra X4200 M2 Server Service Manual May 2007 Sun ESD mat part number 250 1088...
Страница 133: ...Chapter 3 Maintaining the Netra X4200 M2 Server 119...
Страница 134: ...120 Netra X4200 M2 Server Service Manual May 2007...
Страница 146: ...130 Netra X4200 M2 Server Service Manual May 2007...
Страница 154: ...138 Netra X4200 M2 Server Service Manual May 2007...
Страница 172: ...156 Netra X4200 M2 Server Service Manual May 2007...