Netra X4200 M2 Server Service Manual • May 2007
Replacing the Hard Drive Fan Assembly
Caution –
Netra X4200 M2 fans are not hot swappable; you must power off ther
server before replacing. Do not operate the server without fans.
Note –
This fan assembly is also referred to as Fan Tray 1.
Removing the Hard Drive Fan Assembly
1. Prepare the server for hard drive fan removal. See:
■
“Powering Off the Server” on page 28
■
“Disconnecting Cables From the Server” on page 29
■
“Removing the Server From the Rack” on page 30
■
“Performing Antistatic Measures” on page 31
■
“Removing the Top Cover” on page 33