Powering Off the Server
●
Choose a method for shutting down the server from main power mode to
standby power mode.
■
Graceful shutdown
: Use a ballpoint pen or other stylus to press and release
the Power button on the front panel. This causes Advanced Configuration and
Power Interface (ACPI) enabled operating systems to perform an orderly
shutdown of the operating system. Servers not running ACPI-enabled
operating systems will shut down to standby power mode immediately.
■
Emergency shutdown
: Press and hold the Power button for four seconds to
force main power off and to enter standby power mode. When main power is
off, the Power/OK LED on the front panel will begin flashing, indicating that
the server is in standby power mode.
Caution –
When you use the Power button to enter standby power mode, power is
still directed to the Graphics Redirect and Service Processor (GRASP) board and
power supply fans. The Power/OK LED flashes during standby power mode. To
completely power off the server, you must disconnect the AC or DC power cords
from the back of the power supplies.
Содержание Netra X4200 M2
Страница 10: ...x Netra X4200 M2 Server Service Manual May 2007...
Страница 14: ...xiv Netra X4200 M2 Server Service Manual May 2007...
Страница 24: ...10 Netra X4200 M2 Server Service Manual May 2007...
Страница 46: ...32 Netra X4200 M2 Server Service Manual May 2007 Sun ESD mat part number 250 1088...
Страница 133: ...Chapter 3 Maintaining the Netra X4200 M2 Server 119...
Страница 134: ...120 Netra X4200 M2 Server Service Manual May 2007...
Страница 146: ...130 Netra X4200 M2 Server Service Manual May 2007...
Страница 154: ...138 Netra X4200 M2 Server Service Manual May 2007...
Страница 172: ...156 Netra X4200 M2 Server Service Manual May 2007...