Appendix C
Status Indicator LEDs
137
FIGURE C-5
Netra X4200
M2 Internal Status LED Locations
TABLE C-5
Internal LED Functions
LED Name
Description
DIMM Fault LED
(The ejector levers on the
DIMM slots are the LEDs.)
This LED has two states:
• Off: DIMM is operating properly.
• Lit (amber): DIMM has failed.
CPU Fault LED
(on motherboard)
This LED has two states:
• Off: CPU is operating properly.
• Lit (amber): CPU has encountered a voltage or heat error
condition.
GRASP Board Power Status
LED
This LED has two states:
• Off: Standby power is not reaching the GRASP board.
• Lit (green): 3.3V standby power is reaching the GRASP
board.
FT0
FM0
FT0
FM1
FT0
FM2
CPU1 CPU0
DIMM 0
DIMM 2
DIMM 1
DIMM 3
DIMM 0
DIMM 2
DIMM 1
DIMM 3
Front panel of server
Back panel of server
Fan module fault LEDs
DIMM fault LEDs
in DIMM ejector levers
on fan modules
Location of CPU
LEDs on the
motherboard
GRASP board
power status LED
(on the GRASP board)
DIMM SW2
NOTE: PCI Hold-Down
Bracket removed
Содержание Netra X4200 M2
Страница 10: ...x Netra X4200 M2 Server Service Manual May 2007...
Страница 14: ...xiv Netra X4200 M2 Server Service Manual May 2007...
Страница 24: ...10 Netra X4200 M2 Server Service Manual May 2007...
Страница 46: ...32 Netra X4200 M2 Server Service Manual May 2007 Sun ESD mat part number 250 1088...
Страница 133: ...Chapter 3 Maintaining the Netra X4200 M2 Server 119...
Страница 134: ...120 Netra X4200 M2 Server Service Manual May 2007...
Страница 146: ...130 Netra X4200 M2 Server Service Manual May 2007...
Страница 154: ...138 Netra X4200 M2 Server Service Manual May 2007...
Страница 172: ...156 Netra X4200 M2 Server Service Manual May 2007...