100
Netra X4200 M2 Server Service Manual • May 2007
FIGURE 3-74
Lifting the Power Board From the Chassis
5. Continue to
“Installing the Power Distribution Board” on page 100
.
Note –
Do not move the two-pin jumper on the power distribution board from the
default 2-3 position (markings on the board say “Ontario”). This is the required
position for operation of the Netra X4200 M2 server.
Installing the Power Distribution Board
1. Remove the replacement power board from its packaging and place it on an
antistatic mat.
2. Lower the power board into the chassis, aligning the board’s holes with the
standoffs in the chassis (
FIGURE 3-75
).