198
Netra X4200 M2 Server Service Manual • May 2007
Follow these steps to delete a hot-spare from a RAID 1 volume.
1. Select Manage Hot Spare.
2. Remove the current hot spare disk from the list by pressing the + key, - key, or
space bar.
3. After you clear the hot-spare, press C.
4. Select Save Changes then exit this menu to commit the changes.
The Configuration Utility will pause while the hot-spare is being removed.
Creating a Second RAID Volume
The LSI Logic SAS controllers support two active RAID volumes. If one volume is
already configured, follow these steps to add a second volume.
1. In the Configuration Utility, select an adapter from the Adapter List screen.
2. Select the RAID Properties option.
This displays the current volume.
3. Press C to create a new volume.
4. Create the new volume:
■
To create a second RAID 0 volume, continue with Step 2 of
“Creating a RAID 0
Volume” on page 195
.
■
To create a second RAID 1 volume, continue with Step 2 of
“Creating a RAID 1
Volume” on page 196
.
Viewing RAID Volume Properties
Follow these steps to view the properties of RAID volumes.
1. In the Configuration Utility, select an adapter from the Adapter List screen.
2. Select the RAID Properties option.
The properties of the current volume are displayed.
3. If more than one volume is configured, press Alt+N to view the next array.
4. To manage the current array, press Enter when the Manage Array item is
selected.
Содержание Netra X4200 M2
Страница 10: ...x Netra X4200 M2 Server Service Manual May 2007...
Страница 14: ...xiv Netra X4200 M2 Server Service Manual May 2007...
Страница 24: ...10 Netra X4200 M2 Server Service Manual May 2007...
Страница 46: ...32 Netra X4200 M2 Server Service Manual May 2007 Sun ESD mat part number 250 1088...
Страница 133: ...Chapter 3 Maintaining the Netra X4200 M2 Server 119...
Страница 134: ...120 Netra X4200 M2 Server Service Manual May 2007...
Страница 146: ...130 Netra X4200 M2 Server Service Manual May 2007...
Страница 154: ...138 Netra X4200 M2 Server Service Manual May 2007...
Страница 172: ...156 Netra X4200 M2 Server Service Manual May 2007...