Chapter 3
Maintaining the Netra X4200 M2 Server
49
FIGURE 3-25
Path of the Flex Cable From Motherboard to 2- and 4-HDD Connections
Removing the Mass Storage Assembly
1. Prepare the server for mass storage assembly removal. See:
■
“Powering Off the Server” on page 28
■
“Disconnecting Cables From the Server” on page 29
■
“Removing the Server From the Rack” on page 30
■
“Performing Antistatic Measures” on page 31
■
“Removing the Top Cover” on page 33
2. Remove the DVD drive and all the hard drives. See:
■
“Removing the DVD Drive” on page 40
■
“Removing a Hard Drive” on page 43
3. Disconnect the following cables from the mass storage assembly and power
distribution board (
FIGURE 3-24
):
■
System fan
■
Hard drive fan
■
PCI tray power cable
Motherboard
Connection
4-HDD
2-HDD
System Fan
Connector
DIMM locations
Note: Flex circuit
cable assembly
passes through
cutout in chassis
wall.