84
Netra X4200 M2 Server Service Manual • May 2007
FIGURE 3-60
Motherboard Securing Screws and Bus-Bar Screw Locations
5. Use the lifting handle to raise the forward edge of the board until it has
cleared the bus-bar studs.
Caution –
When lifting the board, use caution to avoid damaging the light pipes
and connectors on the rear edge of the motherboard.
6. Slide the board toward the front of the chassis until the connectors and light
pipes are clear of the chassis back panel gasketing. Then raise the motherboard
and remove it from the chassis.