12
Netra X4200 M2 Server Service Manual • May 2007
Powering On the Server
Note –
Before powering on your server for the first time, follow the installation and
cabling instructions provided in the
Netra X4200 M2 Server Setup Guide
, which is
online at the URL described in
“Related Documentation” on page xii
.
Caution –
Do not operate the server without all fans, component heatsinks, air
baffles, and covers installed. Severe damage to server components can occur if the
server is operated without adequate cooling mechanisms.
1. Verify that input (AC/DC) power cords have been connected to the server's
power supplies and that standby power is on.
In standby power mode, the Power/OK LED on the front panel flashes,
indicating that the service processor is working and the system is ready to be
fully powered on to main power mode. See
FIGURE 2-1
for the LED location.
2. Use a ballpoint pen or other stylus to press and release the recessed Power
button on the server front panel. See
FIGURE 2-1
for the Power button location.
When main power is applied to the entire server, the Power/OK LED next to the
Power button lights and remains lit.
Note –
The ILOM Service Processor will boot immediately after AC/DC power is
applied. The host system/motherboard is held in reset mode and the BIOS code will
not execute until the ILOM boot is complete.
FIGURE 2-1
shows the LED location on the server front panel with the bezel open.
Содержание Netra X4200 M2
Страница 10: ...x Netra X4200 M2 Server Service Manual May 2007...
Страница 14: ...xiv Netra X4200 M2 Server Service Manual May 2007...
Страница 24: ...10 Netra X4200 M2 Server Service Manual May 2007...
Страница 46: ...32 Netra X4200 M2 Server Service Manual May 2007 Sun ESD mat part number 250 1088...
Страница 133: ...Chapter 3 Maintaining the Netra X4200 M2 Server 119...
Страница 134: ...120 Netra X4200 M2 Server Service Manual May 2007...
Страница 146: ...130 Netra X4200 M2 Server Service Manual May 2007...
Страница 154: ...138 Netra X4200 M2 Server Service Manual May 2007...
Страница 172: ...156 Netra X4200 M2 Server Service Manual May 2007...