1460/61 INSTRUCTION MANUAL
Page B-3
CLOCK CODE 24:
minute impulse -
the RUN relay activates at XX:XX:58 for 2 seconds
hourly correction -
none
12 hour correction - none
CLOCK CODE 25:
minute impulse
- the RUN relay activates at XX:XX:58 for 2 seconds;
- the RESET relay activates at XX:XX:58 for 2 seconds for the following times:
XX:59:58 to XX:04:58, 4:00:58 (AM and PM) to 4:44:58 (AM and PM),
5:37:58 (AM and PM) to 5:44:58 (AM and PM), 6:00:58 (AM and PM) to
6:44:58 (AM and PM);
- the RESET relay activates at XX:XX:56 for 4 seconds for the following times:
5:00:56 (AM and PM) to 5:36:56 (AM and PM)
hourly correction -
53 cycles beginning at XX:59:02 of:
the RUN relay activates for ½ second and then deactivates for ½ second
12 hour correction - 55 cycles, beginning at the first second each of the times from 5:00:01
(AM and PM) to 5:36:01 (AM and PM) of:
the RUN relay activates for ½ second and then deactivates for ½ second