6-10
DVW-250/250P
6-2. Brush Replacement
2. Brush assembly removal
(1) Disconnect the connector CN913 on the MB-
601 board.
(2) Remove one of the screws, shown in the
figure, which secures the brush base.
(3) Loosen the other screw and move the brush
base in the direction of the arrow.
In this way, the brush and slip ring will
release.
(4) Remove the screw and the brush assembly.
(5) Disconnect the connector on the brush board.
Installation
3. Brush assembly installation
(1) Connect the connector to the brush board.
(2) Temporarily attach the brush assembly to the
brush support with the screw shown in the
figure.
n
Never touch the brush.
(3) Move the brush base (arrow A) while press-
ing down the brush base above the brush
support and temporarily attach the brush
assembly using the other screw.
(4) While pushing the brush base (arrow B),
tighten the screws in steps (2) and (3).
Slip ring
Brush
Brush base
Remove this screw first.
(P2
×
4)
Slip ring
Brush
Brush base
Temporarily fasten
this screw first.
Brush support
Screw(P2
×
4)
B
A