![Sony DVW-250 Скачать руководство пользователя страница 85](http://html.mh-extra.com/html/sony/dvw-250/dvw-250_maintenance-manual_410988085.webp)
6-15
DVW-250/250P
6-4. Upper Drum Assembly Replacement
Tools
• Torque screwdriver bit (for M2): J-6325-380-A
• Hexagon bit (across 1.5 mm)
: J-6326-120-A
• Torque screwdriver (for 3 kg)
: J-6325-400-A
• Upper drum eccentricity gauge (3)
: J-6001-820-A
• Upper drum eccentricity gauge (2)
: J-6001-830-A
• Upper drum eccentricity gauge (5)
: J-6087-000-A
• Upper drum eccentricity gauge (6)
: J-6325-530-A
• L wrench (across 1.5 mm)
: 7-700-736-05
• Cleaning cloth
: 3-184-527-01
• Cleaning fluid
: 9-919-573-01
m
(1) When the upper drum assembly attaches to
the flange, tighten the screws to the following
tightening torque.
• First
: 9.8
×
10
–2
N•m (1 kgf•cm).
• Second: 24.5
×
10
–2
N•m (2.5 kgf•cm).
To tighten the screws to the above tightening
torque, set the torque to 9.8
×
10
–2
N•m
(1 kgf•cm) after attaching the hexagon bit to
the torque screwdriver.
(2) Assemble the upper drum eccentricity gauges
as shown in the figure before use.
Removal
1. Brush cover Removal
Remove the brush cover. (Refer to “6-2. Brush
Replacement”.)
2. Brush assembly removal
Remove the brush assembly. (Refer to “6-2.
Brush Replacement”.)
Upper drum eccentricity gauge (3)
Upper drum eccentricity gauge (2)
Upper drum eccentricity gauge (6)
Upper drum eccentricity gauge (5)