![Sony DVW-250 Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/sony/dvw-250/dvw-250_maintenance-manual_410988025.webp)
1-15
DVW-250/250P
1-8. Battery Terminal Replacement
1.
Remove the battery case. (Refer to “1-5. Removal/
Installation of Cabinet”.)
2.
Remove the two screws and remove the battery
retainer.
3.
Remove the four screws and then replace the battery
terminal.
1-9. Fuse Replacement
Fuse is mounted on FU-63 board. If a trouble occurs on the
unit and when overcurrent flows, the fuse will blow. Fuse
should be replaced with the following parts after removing
a foreign matter that occurs short.
c
The fuse should be replaced after five minutes or more
when the power switch is turned off and the power code is
disconnected.
Part No.
Name
!
1-532-749-11
Fuse, Glass Tube 8 A 125 V
1.
Remove the battery case. (Refer to “1-5. Removal/
Installation of Cabinet”.)
2.
Remove the defective fuse from the fuse holder and
replace it with a new one.
Battery retainer
Screw(B2.6
×
5)
Screw(B2.6
×
5)
Battery case
1-8. Battery Terminal Replacement
1-9. Fuse Replacement
Fuses
Fuse holders
FU-63 board
Screws
(B2.6
×
5)
Battery terminal
Battery retainer
Screws
(B2.6
×
5)