![Sony DVW-250 Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/sony/dvw-250/dvw-250_maintenance-manual_410988050.webp)
3-8
DVW-250/250P
Audio Meter LCD
Discription
AUDIO TEST
OFF
Select the output of the internal audio test signal.(The audio test is not functioned during the SAVE mode.)
OFF : No outputs
1
: 1 kHz, 0 dB
2
: 1 kHz, -20 dB
EXIT
DPR VR
Use DPR-62 board adjustment. (Refer to “5-7. VIDEO Adjustment–2” of maintenance manual part 2.)
REF FLD
80
....................... Reference 1’st Field Adjustment
REF SCH
80
....................... Reference SCH Adjustment
INT 4FSC
80
....................... Internal 4fsc Frequency Adjustment
EXIT
VPR VR1
Use VPR-12 board adjustment. (Refer to “5-7. VIDEO Adjustment–2” of maintenance manual part 2.)
Y LEVEL
....................... Input Y Level Adjustment
R-Y LEVEL
....................... Input R-Y Level Adjustment
B-Y LEVEL
....................... Input B-Y Level Adjustment
EXIT
VPR VR2
Use VPR-12 board adjustment. (Refer to “5-7. VIDEO Adjustment–2” of maintenance manual part 2.)
Y
PHASE
....................... Y Phase Adjustment
Y/R-Y DELAY
....................... Skew Adjustment (Y, R-Y)
Y/B-Y DELAY
....................... Skew Adjustment (Y, B-Y)
EXIT
VPR VR3
Use VPR-12 board adjustment. (Refer to “9-7. VIDEO Adjustment–2”.)
VIDEO IN
80
....................... Input Video Level Adjustment
VIDEO OUT
80
....................... Output Video Level Adjustment
EXIT
A/Ech
Use RF (A/Ech) adjustment. (Refer to “9-5. RF Adjustment”.)
CH-CONDITION
....................... Check the channel condition of A/Ech.
Adjust that only leftmost square on the LCD lights up.
AMP PHS REC
....................... Adjustment data of A/Ech
Ach: xx xx xx
AMP : Amplitude data
Ech: xx xx xx
PHS : Phase data
EXIT
REC : Recording current data
(B/Fch, C/Gch, D/Hch: Same as A/Ech)
AMP ADJUST
Use RF(Amplitude) adjustment. (Refer to “9-5. RF Adjustment”.)
START
....................... Start the adjustment automatically
EXIT
PHS ADJUST
Use RF(Phase) adjustment. (Refer to “9-5. RF Adjustment”.)
START
....................... Start the adjustment automatically
EXIT
REC ADJUST
Use RF(Rec current) adjustment. (Refer to “9-5. RF Adjustment”.)
START
....................... Start the adjustment automatically
EXIT
NV-RAM
Save RF adjustment data (Refer to “5-5. RF Adjustment”.)
LOAD
....................... Load the adjustment data.
SAVE
....................... Save the adjustment data.
EXIT
3-2. DIAG Menu