9-5
DVW-250/250P
9-3-2. Click Position Correction of Tracking
Volume
1.
1
RV401 (A-4) /SST-3
→
Mechanical center (Click
position)
(Tracking control volume)
2.
On the DIAG menu, set PAGE as follows.
PAGE
:
<TEST><TTP><ADJUST/NVRAM>
<ADJUST>
ITEM : TRACON CENTER
3.
Press the SET button.
(Executed the automatic adjustment.)
The “ADJUSTING.....” message is displayed on the
audio meter LCD.
4.
When this adjustment is completed, the “ADJUST
COMPLETE” message is displayed on the audio meter
LCD.
9-3. Servo System Adjustment
9-3-3. Capstan FG Duty Adjustment
1.
On the DIAG menu, set PAGE as follows.
PAGE
:
<TEST><TTP><ADJUST/NVRAM>
<ADJUST>
ITEM : CAP FG DUTY
2.
Press the SET button.
(Executed the automatic adjustment.)
The “ADJUSTING.....” message is displayed on the
audio meter LCD.
3.
When this adjustment is completed, the “ADJUST
COMPLETE” message is displayed on the audio meter
LCD.
If the “ADJUST INCOMPLETE” message is dis-
played, Check the circuit (SST-3 board) relevant to
capstan motor.
SST-3 Board A side
1
A
B
C
D
E
G
H
J
2
3
4
5
6
7
8
9
10
F
RV401
RV2
RV1
TP5
TP6
E6