7-35
DVW-250/250P
7-2-14. CUE/TC Head Azimuth Adjustment
Tools
• Alignment tape ZR2-1
8-960-073-11
• Alignment tape ZR2-1P
8-960-073-61
• Oscilloscope
• Regulated DC power supply
(AC-550/550CE or equivalent)
Setting
1.
Turn the power off.
2.
Remove the top panel.
(Refer to “1-5. Removal/Installation of Cabinet”.)
3.
Remove the battery case.
(Refer to “1-5. Removal/Installation of Cabinet”.)
4.
Connect an oscilloscope.
CH-1: TP802/EQ-54 (CUE PB)
5.
Connect a regulated DC power supply to DC IN
connector on the connector panel.
6.
Turn the power on.
7.
On the setup menu, set the SEARCH speed to
×
2.
(Refer to Section 3-1.)
8.
Insert an alignment tape ZR2-1/1P.
7-2-14. CUE/TC Head Azimuth Adjustment