7-25
DVW-250/250P
7-2-10. Alignment Tape Tracking Check
Tools
• Alignment tape ZR2-1
8-960-073-11
• Alignment tape ZR2-1P
8-960-073-61
• Oscilloscope
• Regulated DC power supply (AC-550/550CE or equiva-
lent)
Setting
1.
Turn the power off.
2.
Remove the top panel.
(Refer to “1-5. Removal/Installation of Cabinet”.)
3.
Open the ornamental panel on the left side panel.
(Refer to “1-13. Tracking Adjustment”.)
4.
Connect an oscilloscope.
CH-1: TP10/MB-601 (REC A)
TRIG: TP8/MB-601 (CF)
5.
Connect a regulated DC power supply to DC IN
connector on the connector panel.
6.
Turn the power on.
7.
On the setup menu, set AUTO TRACKING to OFF.
8.
Insert an alignment tape ZR2-1/1P.
Checks
1. Playback the alignment tape.
Play back the alignment tape ZR2-1/1P (from 00:00 to
15:00).