7-54
DVW-250/250P
5. Tape end sensor position adjustment
(1) Install the tape end sensor and tighten the screw
temporary.
(2) Insert a blank cassette tape. Then the tape will be
threaded.
(3) Set the flat side of the end sensor positioning tool to
contact to the tip of the tape end sensor.
(4) Check that the thin portion (go-end) of the positioning
tool does not touch the tape.
(5) And check that the thick portion (not-go-end) of the
positioning tool does not go to between the tape and
the tape end sensor.
(6) Adjust the position of the tape end sensor so that it
meet above two checks.
(7) Fix the tape end sensor, and tighten the screw.
6. Cleaning
Clean the S-tension guide (S5 guide) using a cleaning cloth
moistened with cleaning fluid.
7. Tape tension check
(1) Insert a FWD back tension measuring cassette tape,
and put the mode into the recording.
(2) Check that the value of the FWD back tension measur-
ing cassette tape at the S side meter meets the specifi-
casion .
Spec. 0.76 to 0.87
X
10
-2
N•m (74 to 85 gf•cm)
If it does not meet, carry out the first step and the
laters again.
End sensor positioning tool
End sensor
Tape
End sensor positioning tool
S side
FWD back tension
measuring cassette
7-3-1. Tension Regurator Adjustment